How to choose the temperature of laboratory resistance furnace?

Time:2024-12-13 Click:0
  

The temperature selection of laboratory resistance furnaces mainly depends on specific experimental requirements, material properties, as well as the specifications and design of the resistance furnace. Here are some suggestions on how to choose the temperature for a laboratory resistance furnace:

1. Select according to experimental requirements
Understand the purpose of the experiment:
Clearly define the maximum temperature required for the experiment and whether precise temperature control is necessary.
Consider material properties:
Different materials have different reactions to temperature, and it is necessary to choose a suitable temperature range.
For example, heat treatment of certain metals may only require lower temperatures, while treatment of special alloys or ceramic materials may require higher temperatures.
2. Select according to the specifications and design of the resistance furnace
Refer to the instruction manual for the resistance furnace:
Understand the maximum operating temperature, temperature uniformity, and temperature control accuracy of the resistance furnace.
Choose the appropriate temperature range:
Laboratory resistance furnaces usually have different temperature ranges to choose from, such as low-temperature furnaces (below 650 ℃), medium temperature furnaces (650-1000 ℃), and high-temperature furnaces (over 1000 ℃, even up to 1800 ℃ or above).
Select the appropriate temperature range based on experimental requirements.
3. Operational suggestions
Preheating and temperature setting:
Before starting the resistance furnace, perform appropriate preheating and set the temperature within a reasonable range of the required operating temperature.
Avoid damage to equipment and materials caused by sudden temperature changes.
Temperature monitoring and adjustment:
During the heating process, closely monitor the temperature changes inside the furnace.
Adjust the heating power or take other measures in a timely manner according to the actual situation to ensure stable temperature control within the set range.
Security protection:
When operating a resistance furnace, it is necessary to wear necessary protective equipment, such as high-temperature resistant gloves, protective goggles, etc.
Ensure that the furnace door is tightly closed to prevent heat waves from spraying out and injuring people.
Shutdown and cooling:
After completing the heating task, gradually reduce the temperature inside the furnace to a safe range before shutting down the equipment.
Avoid turning off the power directly at high temperatures to prevent damage to equipment and heating elements.
In summary, the temperature selection for laboratory resistance furnaces requires comprehensive consideration of experimental requirements, material properties, as well as the specifications and design of the resistance furnace. By setting and monitoring the temperature reasonably, the accuracy and safety of the experimental results can be ensured.